Browser not supported

You are using an old browser that we do not support anymore. Please consider using a modern web browser such as Microsoft Edge, Google Chrome or Firefox for the best website experience.

Muli-UF for the shell builder

Product benefits

  • Simple installation due to trade separation
  • Three inlets for selection
  • High usable volume - 27 l
  • Easy assembly and disassembly of the pump by separate pump tank
  • Fully functional floor drain in the top section

Product information

  • Areas of use:
    • Detached houses
    • For underfloor installation in frost free spaces
  • Housing made out of polyethylene
    • Two different container sizes available
    • Three horizontal DN 100 inlet sockets
    • One socket for DN 50 cable gland
    • One DN 50 ventilation socket
  • Discharge pipe connection
    • Pressure pipe connection according to EN ISO 15493 made of PVC-U; 50-40-R 1¼"
    • Integrated non-return flap
  • A stiffening is not required.
TypeUsable volumeItem

number
Remember
[l]
Pump sump "short" (containers, construction time protection)271203.10.00
Pump sump "long" (containers, construction time protection)271203.10.02
TypeUsed withHeightInlet height Z1Item

number
Pump sump "short" (containers, construction time protection)Muli-UF underfloor lifting plants MWP1670 mm740 mm27 l1203.10.00
Pump sump "long" (containers, construction time protection)Muli-UF underfloor lifting plants MWP2770 mm840 mm27 l1203.10.02

Flashing light

Image
Suitable for
  • Signalling unit with voltage-free fault reporting
  • LipuSmart-P
  • Muli-Max with signalling unit
  • LipuLift-P
Description
  • 230V
  • Power consumption: 70 mA
  • Weight: 0.5 kg

Flashing light

Image

Message system with GSM module

Suitable for
  • All grease separators
  • Grease layer thickness measuring device
  • Pre-tank plants
  • Technical processing systems
  • Quatrix-K backflow preventer type 3F
  • Sinkamat-K (underfloor) duo
  • Muli lifting units
  • Pumping stations
  • Installation sets
Description
  • Parameter via app (Android & iOs)
  • Mains-independent alarm via 12V lead-gel battery
  • Optical and acoustic alarm message
  • Freely configurable inputs
    • 6 digital inputs with LED status display
    • 1 analogue
  • 1 alarm output 12 V
  • Alarm forwarding via SMS to mobile phones
  • For mounting outside the hazardous area
  • Housing: 192 x 150(with cable gland) x 100 mm (WxHxD)
  • Protective doctor: IP54
  • Operating voltage: 230 V/AC 50/60 Hz
  • Translated with www.DeepL.com/Translator (free version)
  • Weight: 2 kg

Cover plate complete incl. drain body


Spare pump unit with basket


maintenance kit


Replacement tube


Signalling unit

Image
Suitable for
  • Faecal matter backflow automatic stop Quatrix-K type 3F
  • All Muli wastewater lifting plants
  • Upstream tank plant mono/duo
  • Muli-Max
  • Sinkamat –K/-KD
  • Sinkamat-Z
  • Sinkamat-Z (underfloor)
    • Duo
  • LipuLift-P
Description
  • Self-charging
  • With floating contact
  • Visual and acoustic
  • Without contact transmitter
  • For mounting outside the potentially explosive atmosphere
  • Dimensions: 175 x 125 x 75 mm W x H x D
  • Protection type: IP65
  • Operating voltage: 230 V/AC 50/60 Hz
  • Ready to plug in with cable: 2 m
  • Weight: 1.4 kg

Signal horn

Image
Suitable for
  • Signalling unit
  • Signalling unit with GSM module
Description
  • Operating voltage: 12V DC
  • Power consumption: 30 mA
  • 62 x 62 x 85 mm (LxWxD)
  • Degree of protection: IP66
  • Noise level: 95 dB(A)
  • Weight: 0.2 kg

Signal horn

Image
Suitable for
  • Signalling unit with voltage-free fault reporting
  • LipuSmart-P
  • Muli-Max with signalling unit
  • LipuLift-P
Description
  • 230V AC
  • Power consumption: 30mA
  • Ø62x85 mm (L/B x T)
  • Protection: IP66
  • 95 dB(A)
  • Weight: 0.3 kg

Connection and flood module set

Image
Suitable for
  • Triplex-K backflow stops
    • DN 100 – DN 150
  • Quatrix-K backflow stops
  • All wastewater lifting plants
  • All separators
Description
  • To report a leak caused for example by a pipe bursting
  • For electrically conducting liquids
  • With volt free contact
  • Visible and audible alarms (approx. 80 dB)
  • Dimensions (width x height x depth): 160 x 120 x 75 mm
  • Protection level: IP 65
  • Operating voltage: 230 V/AC 50/60 Hz
  • Plug and use: 1.4 m
  • Overflow indicator with 10 m cable
  • Weight: 1.1 kg

Extension part

Image
Suitable for
  • Backflow stops for installation in the floor plate
  • Sinkamat-Z (underfloor)
  • Muli-UF (underfloor)
  • Triplex-K
  • Quatrix-K
Description
  • With lip seal
  • Graduated height adjustment every 116 mm
    • For Sinkamat-K maximum 2 extension pieces may be mounted
    • For Triplex-K, Quatrix-K and Muli-UF maximum 1 extension pieces may be mounted
  • Weight: 3.4 kg

Sealing flange

Image
Suitable for
  • Backflow stops for installation in the floor plate
  • Sinkamat-Z (underfloor)
  • Muli-UF (underfloor)
  • Triplex-K
  • Quatrix-K
Description
  • For building into waterproof concrete
    • Maximum groundwater level: 2 m
  • Weight: 4.2 kg

Pressure line set 50 mm diam.

Image
Suitable for
  • Sinkamat-K (underfloor)
    • Mono
    • Duo
  • Muli-UF (underground)
Description
  • 5 m pressure tube ext. diam. 50 (ID 42) with 1 ¼" PVC adaptor socket
  • Max. pressure: 6 bar
  • Weight: 4 kg