Muli-Max – load class D 400

Product benefits
- Total installation depth up to 3000 mm
- Inlet depth max. 2225 mm
- Pneumatic level switch for high operational safety
- Buoyancy-proof against ground water level up to 0.675 m from ground level
- Optional: foot for buoyancy safety completely up to ground level OK
- Installation without on-site concrete work
- Accessible by all vehicles, including trucks
Product information
- Application areas
- Single and multiple family houses
- Office buildings
- Industrial buildings
- Pressure Drainage
- Single or double pump station for below ground installation from polyethylene
- Tested according to EN 12050
- With automatic above water coupling
- Suitable for submersible pumps from ACO
- Pressure connection from PE-HD DN 50 (OD 63 mm), with ball valve and compression fitting 63 x 63 mm OD
- Installation height: 2,200-3,000mm
- Connecting height (from top of tank to center of pressure connection): 1,150 – 1,950 mm mm
- Two inlets OD 160 mm, connecting height top of cover until center of pipe: 1,425 – 2,225 mm, one sealing ring in scope of delivery
- Two inlets OD 110 mm, connecting h height top of cover until center of pipe height: 1,425 mm – 2,225 mm
- Two connections OD 110 mm for cable pipe and ventilation, connecting height top of cover until center of pipe height: 70 – 1,570 mm
- Connection with pipe sleeve R ½” for rinsing connection / vacuum interruption (accessories)
- Manhole cover (optionally locked)
- Load class: D400
- Opening: 600 mm according to EN 124
- Without ventilation
- With lifting tool
- With load distribution plate: OD 1550 mm/ID 625 mm, height 200 mm from reinforced concrete
- With raising tube
- Height: 1,300 mm
- Height-adjustable, inclusive sealing ring
- Suitable submerged pumps mono/duo
Switching device, ACO Multi Control Mono
Suitable for
- Muli-Max
- Mono-plant
Description
- For pumps up to 5,5 kW
- Plug and use with 1.5 m mains cable
- EEC 16-plug with phase inverter
- 20 m pneumatic control line 10 x 1.5 mm
- Dynamic pressure bell
- Cable duct
- Operating voltage: 400 V
- Frequency: 50/60 Hz
- Control voltage: 230 V/AC
- Current consumption when idling: max 8 VA
- Temperature range: -20 to +60 °C
- IP 54 protection
- Weight: 4 kg
Switching device, ACO Multi Control Mono Professional
Suitable for
- Muli-Max
- Mono-plant
Description
- For pumps up to 5,5 kW
- Plug and use with 1.5 m mains cable
- EEC 16-plug with phase inverter
- 20 m pneumatic control line 10 x 1.5 mm
- Dynamic pressure bell
- Cable duct
- Operating voltage: 400 V
- Frequency: 50/60 Hz
- Control voltage: 230 V/AC
- Current consumption when idling: max 8 VA
- Temperature range: -20 to +60 °C
- IP 54 protection
- With Modbus RTU - functionality for connection to the building management system
- Weight: 4 kg
Switching device, ACO Multi Control Duo Professional incl. Dynamic pressure bell
Suitable for
- Muli-Max
- Duo-plants
- Powerlift–P
- Muli-Flex
Description
- For pumps up to 5,5 kW
- Plug and use with 1.5 m mains cable
- EEC 16-plug with phase inverter
- 20 m pneumatic control line 10 x 1.5 mm
- Dynamic pressure bell
- Cable duct
- Operating voltage: 400 V
- Frequency: 50/60 Hz
- Control voltage: 230 V/AC
- Current consumption when idling: max 10 VA
- Temperature range: -20 to +60 ° C
- IP 54 protection
- Weight: 5.4 kg
Switching device, ACO Multi Control Duo incl. Dynamic pressure bell
Suitable for
- Muli-Max
- Duo-plants
- Powerlift–P
- Muli-Flex
Description
- For pumps up to 5,5 kW
- Plug and use with 1.5 m mains cable
- EEC 16-plug with phase inverter
- 20 m pneumatic control line 10 x 1.5 mm
- Dynamic pressure bell
- Cable duct
- Operating voltage: 400 V
- Frequency: 50/60 Hz
- Control voltage: 230 V/AC
- Current consumption when idling: max 10 VA
- Temperature range: -20 to +60 ° C
- IP 54 protection
- For pumps up to 5,5 kW
- Plug and use with 1.5 m mains cable
- EEC 16-plug with phase inverter
- 20 m pneumatic control line 10 x 1.5 mm
- Dynamic pressure bell
- Cable duct
- Operating voltage: 400 V
- Frequency: 50/60 Hz
- Control voltage: 230 V/AC
- Current consumption when idling: max 10 VA
- Temperature range: -20 to +60 ° C
- IP 54 protection
- Weight: 5.4 kg
Flashing light
Float switch
Suitable for
- For faecal and non-faecal wastewater
- MultiControl controls as float switches
- MultiControl controls as additional High alarm float
Description
- Housing: PRE-ELEC PP
- Degree of protection: IP68
- Switch voltage: 4-40 V
- Switch current: 1-100 mA
- Connection cable: 10m
- Switch inclination: 10°
- Protection class: II 1G Ex ia IIC T6 Ga
Signalling unit
Suitable for
- Faecal matter backflow automatic stop Quatrix-K type 3F
- All Muli wastewater lifting plants
- Upstream tank plant mono/duo
- Muli-Max
- Sinkamat –K/-KD
- Sinkamat-Z
- Sinkamat-Z (underfloor)
- Duo
- LipuLift-P
Description
- Self-charging
- With floating contact
- Visual and acoustic
- Without contact transmitter
- For mounting outside the potentially explosive atmosphere
- Dimensions: 175 x 125 x 75 mm W x H x D
- Protection type: IP65
- Operating voltage: 230 V/AC 50/60 Hz
- Ready to plug in with cable: 2 m
- Weight: 1.4 kg
Message system with GSM module
Suitable for
- All grease separators
- Grease layer thickness measuring device
- Pre-tank plants
- Technical processing systems
- Quatrix-K backflow preventer type 3F
- Sinkamat-K (underfloor) duo
- Muli lifting units
- Pumping stations
- Installation sets
Description
- Parameter via app (Android & iOs)
- Mains-independent alarm via 12V lead-gel battery
- Optical and acoustic alarm message
- Freely configurable inputs
- 6 digital inputs with LED status display
- 1 analogue
- 1 alarm output 12 V
- Alarm forwarding via SMS to mobile phones
- For mounting outside the hazardous area
- Housing: 192 x 150(with cable gland) x 100 mm (WxHxD)
- Protective doctor: IP54
- Operating voltage: 230 V/AC 50/60 Hz
- Translated with www.DeepL.com/Translator (free version)
- Weight: 2 kg
Signal horn
Signal horn
Air bubble injection
Outdoor cabinet
Outdoor cabinet for local pressure pipes an controller
Suitable for
- Muli-Max
- Powerlift–P
- LipuLift-P-B/P-D
Description
- Dimension: 2000 x 806 x 335 mm (H x W x D)
- With reserve space for installation of an on-site backflow loop according to DIN 12056-4 and 1986-100
- DN 50 – DN 150
- With mounting plate incl. base
- With lamp
- With CEE32 and work socket with earth contact
- With heating and thermostat
- With security lock
- Weight: 76 kg
Pressure pick-up
Pressure pick-up
Safety barrier
Guide strap
Guide strap
Flushing connection
Vacuum relief valve
Compression fitting 63 x 63 mm
Compression fitting 63 x 75 mm