Submerged pump


Product information

  • Underwater pumps with
    • Channel impeller
    • Free flow impeller or Cutting mechanism
Characteristic curve
DescriptionUsed withDescriptionItem

number
Remember
ImageSITA 200 N-ex-G
  • Muli-Max–Series
  • For water with faecal matter
  • Screws and nuts made of stainless steel
  • Cutting mechanism and cutting plate made of stainless steel 60 HRC
  • ATEX-Certification
  • Performance
    • P1 = 1,78 kW
    • P2 = 1,5 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • Electric wire typ: 4G1,5+3x1 – 10 m
  • IP 68 protection
  • Operating mode: S1
0178.64.29
Sita 300 N-ex-G
  • Muli-Max–Series
  • For water with faecal matter
  • Screws and nuts made of stainless steel
  • Cutting mechanism and cutting plate made of stainless steel 60 HRC
  • ATEX-Certification
  • Performance
    • P1 = 2,76 kW
    • P2 = 2,2 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • Electric wire typ: 4G1,5+3x1 – 10 m
  • IP 68 protection
  • Operating mode: S1
0178.64.31
ImageSAT-V 75/2/50/D
  • Muli-Max F–Series
  • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With free flow impeller
  • Performance
    • P1= 0,70 kW
    • P2= 0.55 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • With motor protection
  • Granulation: 40 mm
0178.08.54
SAT-V 150/2/50/D
  • Muli-Max F–Series
  • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With free flow impeller
  • Performance
    • P1= 1.50 kW
    • P2= 1.10 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • With motor protection
  • Granulation: 50 mm
0178.08.55
ImageSat-100/D
  • Muli-Max F–Series
  • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With open impeller
  • Performance
    • P1= 1.15 kW
    • P2= 0.89 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • Granulation: 10/16 mm (with/out strainer)
0178.08.56
Sat-150/D
  • Muli-Max F–Series
  • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With open impeller
  • Performance
    • P1= 1.54 kW
    • P2= 1.14 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • Granulation: 10/16 mm (with/out strainer)
0178.08.57
Sat‑200/D
  • Muli-Max F–Series
  • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With open impeller
  • Performance
    • P1= 2.03 kW
    • P2= 1.50 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • Granulation: 12/16 mm (with/out strainer)
0178.08.58
Characteristic curve
DescriptionUsed withDescriptionItem

number
Image
  • SITA 200 N-ex-G
    • Muli-Max–Series
    • For water with faecal matter
  • Screws and nuts made of stainless steel
  • Cutting mechanism and cutting plate made of stainless steel 60 HRC
  • ATEX-Certification
  • Performance
    • P1 = 1,78 kW
    • P2 = 1,5 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • Electric wire typ: 4G1,5+3x1 – 10 m
  • IP 68 protection
  • Operating mode: S1
0178.64.29
  • Sita 300 N-ex-G
    • Muli-Max–Series
    • For water with faecal matter
  • Screws and nuts made of stainless steel
  • Cutting mechanism and cutting plate made of stainless steel 60 HRC
  • ATEX-Certification
  • Performance
    • P1 = 2,76 kW
    • P2 = 2,2 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • Electric wire typ: 4G1,5+3x1 – 10 m
  • IP 68 protection
  • Operating mode: S1
0178.64.31
Image
  • SAT-V 75/2/50/D
    • Muli-Max F–Series
    • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With free flow impeller
  • Performance
    • P1= 0,70 kW
    • P2= 0.55 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • With motor protection
  • Granulation: 40 mm
0178.08.54
  • SAT-V 150/2/50/D
    • Muli-Max F–Series
    • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With free flow impeller
  • Performance
    • P1= 1.50 kW
    • P2= 1.10 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • With motor protection
  • Granulation: 50 mm
0178.08.55
Image
  • Sat-100/D
    • Muli-Max F–Series
    • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With open impeller
  • Performance
    • P1= 1.15 kW
    • P2= 0.89 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • Granulation: 10/16 mm (with/out strainer)
0178.08.56
  • Sat-150/D
    • Muli-Max F–Series
    • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With open impeller
  • Performance
    • P1= 1.54 kW
    • P2= 1.14 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • Granulation: 10/16 mm (with/out strainer)
0178.08.57
  • Sat‑200/D
    • Muli-Max F–Series
    • For water without faecal matter
  • Housing made of GG
  • 3-phase current version
  • With open impeller
  • Performance
    • P1= 2.03 kW
    • P2= 1.50 kW
  • Voltage: 400 V, 50 Hz
  • Rev count: 2,900 rpm
  • IP 68 protection
  • Granulation: 12/16 mm (with/out strainer)
0178.08.58